Mercedes-Benz Automatic Transmission Emergency Ambulance
Overview Parameters Mercedes-Benz ward-type 2.0T automatic transmission petrol ambulance car ...
Sprinkling, landscaping, cooling and dust removal, temporary fire fighting,drought-resistant wat...
Roadwater truck is suitable for all kinds of road surface flushing, tree, green belt, lawn greeni...
6×4 371hp 20CBM 20T Water Browser Sprinkler Spray Truck Water Tank Truck Fire Truck: 1. Oil ...
Sprinkler truck applies to flush road,trees,green belts,high-altitude building suppress dust,spra...
0086-13322938626
FORD negative pressure ambulance is equipped negative pressure device can form negative pressure in the car to prevent from spreading in the car and provide medical care in the car.
FORD 2.2T diesel Negative Pressure ICU for COVID-19 patients transport ambulance car
Compared with the “soft” equipment such as masks and protective clothing, the negative pressure ambulance known as the “super large N95” is the first “hard” equipment to realize the supply guarantee. Novel corona virus pneumonia has been delivered to nearly 700 negative ambulances in Hubei province throughout the country, basically meeting the needs of new Hubei and Wuhan’s new pneumonia cases.
Quick Details
Size of ambulance | 5780×2000×2690 |
A/C | Include |
Chassis brand | FORD |
Horsepower | 136hp(Euro 5) |
Outside | Provide free logo design,both sides doors pasted with cross mark |
Oxygen supply system |
One 10-liter oxygen cylinders One directly connected oxygen cylinder with oxygen pressure reducing valve |
Upholstery | ABS composite material, high-duty,anti-microbial |
Negative pressure cabin Size | 620x420x320mm |
Medium efficiency filter Size | 450x300x21mm |
High efficiency filter Size | 450x300x46mm |
Applications
Ambulance equipped negative pressure system for the care and transportation of infectious patients,such as SARS, COVID-19.
Compared with ordinary ambulances, the biggest feature of negative pressure ambulances is that they are equipped with negative pressure equipment to achieve “negative pressure isolation” by making the air pressure in the vehicle lower than the external atmospheric pressure. At the same time, on the basis of ensuring the fresh air input, the air in the medical cabin is filtered and sterilized and then discharged out of the vehicle, so as to minimize the probability of cross infection between doctors and patients in the cabin. As the “weapon” of epidemic prevention and control, “standard configuration” of negative pressure ambulance is negative pressure system and negative pressure isolation cabin, which is also the necessary key equipment of negative pressure ambulance.
Negative pressure system
1. Through the negative pressure overhead air-conditioning independent air conditioner (independent of the cabin air conditioner), the air conditioner draws fresh air from the outside into cold air and enters the negative pressure medical cabin to ensure that the fresh and clean air enters the medical cabin.
2.Using the principle of fluid mechanics, a step pressure is generated from the side of the medical staff to the side of the patient, forming a uniform and continuous directional airflow, and finally sterilized and filtered out of the car, thereby maximizing the protection of the medical staff
3. In the negative pressure chamber, the principle of fluid mechanics is used to form a directional air flow from the clean area (medical staff area) to the source area (patient area), so that the dead angle and vortex of the air flow in the negative pressure chamber are minimized. The air pressure in the negative pressure compartment is -50Pa to -30Pa
4. The gas discharged from the directional flow in the negative pressure chamber should be discharged into the atmosphere after being sterilized by a high-efficiency filter, and must not be recycled into the negative pressure chamber. The filtration rate for aerosols with a particle size of 0.3 microns is greater than 99.95%.
5.The negative pressure system is equipped with an alarm device, which will generate an alarm when it is lower than the set negative pressure value;
6. Ozone generator is used in the negative pressure sterilization device to ensure the complete elimination of the bacteria in the medical cabin. It also has ozone concentration monitoring to prevent the ozone concentration from being too high and causing harm to the human body.
Competitive Advantage
1. The wide space of the medical emergency ambulance in the top of the center axis of the whole line, together with the humanized configuration such as the front and rear stereo air conditioning, creates a more comfortable driving experience for you
2. 2.2T large diesel exhaust, high speed for transportation
3. Engine use German Continental company newest technology
4. Gearbox use German GFT 6-speed, equipped with Multicone synchronizer,the noise is greatly reduced
5. Ambulance equip with negative pressure system to protect medical staff and warranty infection victim transport
6. Ambulance equipped with complete medical equipment with economic price
7. Chassis is American high quality brand FORD TRANSIT
Product Details
Customer Services
Pre sale service
— Technical communication with engineer
— Factory and workshop visit
— Making design drawings
After Sale Service
— Overseas installation & commissioning
— Overseas and spare parts support
— Technical and spare parts support
Truck
According to your request, choose good chassis and refit it to truck.
Upper Body design function parts.
Customization
Spare Parts on trucks as tank and box.
|
Product Parameters
Chassis Specification | |||
Truck model | CLW5041XJHJ5 | ||
Cab | FORD V348 CABIN | ||
Driving Type | 4*2 Left hand driving | ||
Max Speed (km/h) | 140 | ||
Overall dimension(mm) | 5780×2000×2690 | ||
Ambulance Van dimension (mm) | 3100×1700×1850 | ||
GVW(kg) | 3700 | ||
Mass in working order(kg) | 2690 | ||
Wheelbase(mm) | 3750 | ||
Approach/Departure Angel | 22/25 | ||
Tire | 215/75R16LT | ||
Clutch | Single-plate dry diaphragm spring clutch | ||
Steering | Hydraulic steering with power assistance | ||
Gear box | 6-Speed gear box | ||
Suspension | Front | Front Mcpherson independent suspension | |
Rear | Rear Hotchkiss suspension leaf spring | ||
Engine | Model | DURATORQ4D225H | |
Fuel Type | Diesel | ||
Type | 2.2T In-line four cylinder supercharged cold cylinder direct injection | ||
Exhaust(ml) | 2198 | ||
Max output power/ rotating speed(hp/rpm) | 136/3750 | ||
Max Torque/rotating speed(nm/rpm) | 350/2100 | ||
Braking system | Service Brake | Air brake and dish brake | |
Park Brake | Spring energy | ||
Eletric system | 24v | ||
Upper-Body specification | |||
basic configuration | Medical warehouse air conditioning and heating | ||
Circuits and medical appliances | Alarm and warning system | Long Row Standard Police Lights Or Various popular special-shaped police lights | |
100 watt siren and handheld control | |||
Power supply system | Original vehicle power supply system | ||
External power supply system | |||
AC circuit protection system | |||
Available for usb / 12v / 220v uninterruptible power supply | |||
1000w Sine wave inverter system | |||
control system | Micro-circuit centralized control system
Cockpit emergency start system Integrated switch control LCD display equipment |
||
Oxygen supply system | two 10-liter oxygen cylinders, special shock-absorbing clamps | ||
2 sets oxygen pressure reducing valves, | |||
humidification bottles | |||
hidden oxygen pipes, international oxygen ports | |||
Ventilation system | Two-way ventilation fan | ||
Disinfection system | Mosaic UV anti-virus lamp | ||
Light system | Medical special led light
Rear spotlight Car left and right side lights |
||
Intercom system | Front and rear window intercom, one-way control | ||
Medical warehouse interior | The interior adopts abs conforming material or overall mold forming process. The surface is smooth, antibacterial, high hardness, and the floor is easy to clean. | ||
partition wall, | |||
push-pull observation window on the partition wall, | |||
pill cabinet behind the partition wall, | |||
fixed oxygen cylinder beside the pill cabinet, | |||
long seat belt and seat belt pre-buried, | |||
Seat system | 3 seat long soft seat on the right | ||
Folding reverse independent seat with three-point safety belt | |||
First aid | Automatic loading stretcher, | ||
sliding infusion stand with 2 sets of infusion bottle hooks, | |||
fire extinguisher | |||
Exterior | Black solar film on the left side of the medical warehouse, semi-transparent frosted film on the right and rear sides, cross signs on the left and right doors | ||
Negative pressure isolation room | Size | 1900x680x500mm | |
Useful | infectious victim isolation and transport | ||
Material | Durable and | ||
Endurance | 8h when full electric | ||
Noisy | ≤56dB(A) | ||
Ventilation volume | ≥75L/min | ||
Other:equip the alarm system when pressure not enough and low power supply | |||
Negative pressure system |
Negative pressure cabin Size | 620x420x320mm | |
Medium efficiency filter Size | 450x300x21mm | ||
Highefficiency filter Size | 450x300x46mm | ||
Working Voltage | DC12V | ||
Working Current | ≤20A | ||
Air exhaust rate | ≥800m3/h | ||
Negative pressure | 20-30Pa | ||
Negative pressure Accuracy | 1.0Pa | ||
Air circulation ratio | 800m3/Cabin volume | ||
Efficient filter | 99.99% |